In the display order below, the held evidence set runs from Ecogenica EG-260FR to Ecogenica EG-260FRC; its published labels start with E1 and end with P7. The source and each model-mapping record remain visible on this page.

Compatible models

This result is published only for the models explicitly covered by the source evidence.

  • EcogenicaEG-260FR
  • EcogenicaEG-260FRC

Published codes

Fault code

E1

Red — urgent safety concern

Red means the documented fault involves safety-critical, leak, electrical, refrigerant, lockout or overheat language.

Documented as Protection of high pressure switch.

A licensed technician confirms the actual cause.

View the canonical E1 result

Fault code

E3

Red — urgent safety concern

Red means the documented fault involves safety-critical, leak, electrical, refrigerant, lockout or overheat language.

Documented as Electric overheating protection.

A licensed technician confirms the actual cause.

View the canonical E3 result

Fault code

E7

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as Compressor exhaust temperature high temperature protection.

A licensed technician confirms the actual cause.

View the canonical E7 result

Fault code

E8

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as Communication failure.

A licensed technician confirms the actual cause.

View the canonical E8 result

Fault code

P1

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as Water tank temperature sensing fault.

A licensed technician confirms the actual cause.

View the canonical P1 result

Fault code

P3

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as Evaporator temperature sensor error.

A licensed technician confirms the actual cause.

View the canonical P3 result

Fault code

P4

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as Compressor suction temperature sensor error.

A licensed technician confirms the actual cause.

View the canonical P4 result

Fault code

P5

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as Ambient temperature sensor error.

A licensed technician confirms the actual cause.

View the canonical P5 result

Fault code

P7

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as Compressor discharge temperature sensor error.

A licensed technician confirms the actual cause.

View the canonical P7 result

Official source

Where this result comes from

Ecogenica. Ecogenica FRE/FREC Owners Manual, March 2024 — official source moved; archived evidence retained at evidence/ecogenica-fre-frec-owners-manual.pdf. Retrieved .