Fault code
bb
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Low heat pump capacity.
A licensed technician confirms the actual cause.
View the canonical bb resultVerified shared codeset
Every result below passed dual extraction agreement and source-anchor checks.
DISPLAY codeset
38 documented fault codes, shared only by the compatible models listed here.
In the display order below, the held evidence set runs from Emerald Energy HPRX300E-1 to Emerald Energy HPRX300E-1; its published labels start with bb and end with PA. The source and each model-mapping record remain visible on this page.
This result is published only for the models explicitly covered by the source evidence.
Fault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Low heat pump capacity.
A licensed technician confirms the actual cause.
View the canonical bb resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as High temperature protection of inverter module.
A licensed technician confirms the actual cause.
View the canonical C7 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Over load protection of E-heater ( 16 A).
A licensed technician confirms the actual cause.
View the canonical CH resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as There is not enough water in the water tank.
A licensed technician confirms the actual cause.
View the canonical E0 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Communication malfunction between controller and main control board.
A licensed technician confirms the actual cause.
View the canonical E2 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Water tank temperature sensor error (T5L).
A licensed technician confirms the actual cause.
View the canonical E4 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as ODU heat exchanger temperature sensor error (T3).
A licensed technician confirms the actual cause.
View the canonical E5 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as ODU ambient temperature sensor error (T4).
A licensed technician confirms the actual cause.
View the canonical E6 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as E0 protection continuously occurs three times.
A licensed technician confirms the actual cause.
View the canonical E8 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Suction temperature sensor error (Th).
A licensed technician confirms the actual cause.
View the canonical E9 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Discharge temperature sensor error (Tp).
A licensed technician confirms the actual cause.
View the canonical EA resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as EEPROM chip error.
A licensed technician confirms the actual cause.
View the canonical EE resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Clock chip error.
A licensed technician confirms the actual cause.
View the canonical EF resultFault code
Red means the documented fault involves safety-critical, leak, electrical, refrigerant, lockout or overheat language.
Documented as Leakage error of e-heater.
A licensed technician confirms the actual cause.
View the canonical EP resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as DC bus low voltage protection.
A licensed technician confirms the actual cause.
View the canonical F1 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Low super-heat of discharge protection.
A licensed technician confirms the actual cause.
View the canonical F2 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Electric expansion valve joint fault.
A licensed technician confirms the actual cause.
View the canonical F6 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Communication malfunction between main control board and inverter board.
A licensed technician confirms the actual cause.
View the canonical H1 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Three times L0 protect.
A licensed technician confirms the actual cause.
View the canonical H4 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as The DC fan motor malfunction.
A licensed technician confirms the actual cause.
View the canonical H6 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Voltage protection.
A licensed technician confirms the actual cause.
View the canonical H7 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as E-heater error (Current is less than 2 A when e - heater operating).
A licensed technician confirms the actual cause.
View the canonical HC resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Inverter module board EEPROM malfunction.
A licensed technician confirms the actual cause.
View the canonical HF resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as 10 times H6 in 2 hours.
A licensed technician confirms the actual cause.
View the canonical HH resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Smart Grid signal error.
A licensed technician confirms the actual cause.
View the canonical HP resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as IPM module over current or weak magnetic protection.
A licensed technician confirms the actual cause.
View the canonical L0 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Module or winding high temperature protection.
A licensed technician confirms the actual cause.
View the canonical L1 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Bus voltage protection or missing phase.
A licensed technician confirms the actual cause.
View the canonical L2 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as EEPROM 337J Fault Protection.
A licensed technician confirms the actual cause.
View the canonical L3 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Out of step, Zero speed protection and so on.
A licensed technician confirms the actual cause.
View the canonical L4 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Phase loss, short circuit to ground, motor winding, inductance and other abnormal protection.
A licensed technician confirms the actual cause.
View the canonical L5 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Phase loss, short circuit to ground, motor winding, inductance and other abnormal protection.
A licensed technician confirms the actual cause.
View the canonical LA resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as PFC protection.
A licensed technician confirms the actual cause.
View the canonical Lb resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as System low pressure protection (low pressure switch ).
A licensed technician confirms the actual cause.
View the canonical P0 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as System high pressure protection (high pressure switch ).
A licensed technician confirms the actual cause.
View the canonical P1 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Over load protection of inverter compressor.
A licensed technician confirms the actual cause.
View the canonical P3 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as High discharge temperature (Tp) protection.
A licensed technician confirms the actual cause.
View the canonical P4 resultFault code
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Documented as Low water temperature protection.
A licensed technician confirms the actual cause.
View the canonical PA resultOfficial source
Emerald Energy. Emerald Heat Pump Split System HPRX300E-1 Instructions. Retrieved .