Skip to content
Heat Pump Fault Finder AU

Exact model

Thermann 300THC25P-H

Fault-code coverage and official support for this exact registered model.

Evidence-led introduction

About this exact model

Official scope evidence connects Thermann 300THC25P-H to the Smart Life app error display; the fault-code link on this page follows that documented controller relationship.

Evidence: Thermann Integrated R290 Heat Pump Installer’s and Owner’s Guide

The captured model material records tank volume 287 L and refrigerant R290 for Thermann 300THC25P-H, details that help distinguish the exact variant rather than merely restating a family name.

Evidence: Thermann Integrated R290 Heat Pump Installer’s and Owner’s Guide, PDF page 11

The CER register lists Thermann 300THC25P-H as current, with eligibility recorded from 27 July 2024 to 31 December 2030; this dated status is separate from the controller evidence used for fault-code compatibility.

Evidence: CER ASHP item 1105

Model record

Current register listing

Registry source: CER ASHP item 1105.

Source-checked facts

Model specifications

Blank or ambiguous specifications are left out. Each value below points to its register record or captured manual page.

Source-checked specifications for this exact heat-pump model
SpecificationValueSource
CER listing statusCurrentCER ASHP item 1105
CER eligible from27 July 2024CER ASHP item 1105
CER eligible to31 December 2030CER ASHP item 1105
Zone 1 certificates25 STCsCER ASHP item 1105
Zone 2 certificates22 STCsCER ASHP item 1105
Zone 3 certificates30 STCsCER ASHP item 1105
Zone 4 certificates32 STCsCER ASHP item 1105
Zone 5 certificates32 STCsCER ASHP item 1105
Power input2.6 (element) / 2.0 (no element) kWThermann Integrated R290 Heat Pump Installer’s and Owner’s Guide, PDF page 11
RefrigerantR290Thermann Integrated R290 Heat Pump Installer’s and Owner’s Guide, PDF page 11
Tank volume287 LThermann Integrated R290 Heat Pump Installer’s and Owner’s Guide, PDF page 11
Weight125 kgThermann Integrated R290 Heat Pump Installer’s and Owner’s Guide, PDF page 11

Evidence-backed coverage

Verified fault-code set

These links appear only when official documentation supports the model-to-controller connection.

  • APP codeset

    Smart Life app error display

    6 documented codes

    Thermann Integrated R290 Heat Pump Installer’s and Owner’s Guide lists this covered model on page 1.

Manufacturer route

Official support

Active support recorded

This brand is recorded as active in the Australian market.

Thermann owner Reece continues to publish current Australian heat-pump owner and warranty guidance.

Status checked · Research source

Domestic integrated R290: 7 years tank, 3 years tank labour and refrigeration components and labour, and 1 year other parts and labour.