QDC0030PD-11 digital controller display

7 documented fault codes, shared only by the compatible models listed here.

In the display order below, the held evidence set runs from Quantum 150-08ACW-134 to Quantum 340-17ACW-134; its published labels start with E01 and end with E08. The source and each model-mapping record remain visible on this page.

Compatible models

This result is published only for the models explicitly covered by the source evidence.

  • Quantum150-08ACW-134
  • Quantum270-11AC3-134
  • Quantum340-11AC3-134
  • Quantum340-17ACW-134

Published codes

Fault code

E01

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as an open or shorted water-temperature sensor circuit.

A licensed technician confirms the actual cause.

View the canonical E01 result

Fault code

E02

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as an open or shorted compressor-temperature sensor circuit.

A licensed technician confirms the actual cause.

View the canonical E02 result

Fault code

E03

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as an open or shorted evaporator-temperature sensor circuit.

A licensed technician confirms the actual cause.

View the canonical E03 result

Fault code

E04

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as compressor overload protection.

A licensed technician confirms the actual cause.

View the canonical E04 result

Fault code

E05

Red — urgent safety concern

Red means the documented fault involves safety-critical, leak, electrical, refrigerant, lockout or overheat language.

Documented as compressor overheat protection above the H95 setting.

A licensed technician confirms the actual cause.

View the canonical E05 result

Fault code

E06

Red — urgent safety concern

Red means the documented fault involves safety-critical, leak, electrical, refrigerant, lockout or overheat language.

Documented as compressor overheat protection above 105 °C.

A licensed technician confirms the actual cause.

View the canonical E06 result

Fault code

E08

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as an open or shorted optional ambient-temperature sensor circuit.

A licensed technician confirms the actual cause.

View the canonical E08 result