Verified codeset result
The manufacturer documentation publishes fault code E02 for the QDC0030PD-11 digital controller display, mapped to the affected Quantum models listed below.
Fault code E02
Quantum QDC0030PD-11 digital controller display: E02
QDC0030PD-11 digital controller display

Last verified from the captured official source review.
E02 meaning for this display codeset
This page isolates Quantum fault code E02 for the QDC0030PD-11 digital controller display. It does not combine the Quantum E02 meaning with another controller or codeset.
Before applying the Quantum E02 meaning, confirm the affected model uses the QDC0030PD-11 digital controller display. In that controller namespace, E02 means documented as an open or shorted compressor-temperature sensor circuit.
The Quantum Domestic Heat Pump Owner Manual QDC0030PD-11 source anchor on page 26 supports this Quantum E02 record for the QDC0030PD-11 digital controller display.
The permanent source key quantum-qdc0030pd-11-display E02 keeps the quantum-qdc0030pd-11-display E02 controller/code pairing distinct in publication.
What the documentation says
Documented as an open or shorted compressor-temperature sensor circuit.
This is a paraphrase of the manufacturer’s documentation. A licensed technician confirms the actual cause.
Severity
Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.
Source-grounded diagnosis context
Documented causes
The compressor-temperature sensor circuit is open or shorted.
Source: Quantum Domestic Heat Pump Owner Manual QDC0030PD-11, PDF page 26
Owner outcomes
What owners reported next
This aggregate appears after at least three structured reports for this exact codeset and code. Counts come from fixed choices only. Private notes are never shown here.
- Fixed
- Unit replaced
- Still unresolved
Repair, replacement and warranty context
Start with diagnosis, then compare repair and replacement
An amber classification usually calls for a diagnosis and repair quote, not automatic replacement. Compare parts availability, repair cost and system age only after the fault has been confirmed by an appropriately licensed professional.
This brand has a verified current Australian support route, so check warranty coverage with the manufacturer before authorising paid repair or replacement work.
Affected models
Every model mapped to this codeset is listed with the evidence match state used by this site.
- Quantum150-08ACW-134Exact manual match
- Quantum270-11AC3-134Exact manual match
- Quantum340-11AC3-134Exact manual match
- Quantum340-17ACW-134Exact manual match
Related codes from this codeset
These codes appear in the same documented controller or display codeset.
- E01
Documented as an open or shorted water-temperature sensor circuit.
- E03
Documented as an open or shorted evaporator-temperature sensor circuit.
- E04
Documented as compressor overload protection.
- E05
Documented as compressor overheat protection above the H95 setting.
- E06
Documented as compressor overheat protection above 105 °C.
- E08
Documented as an open or shorted optional ambient-temperature sensor circuit.
Choose the right next step
Warranty or local repair?
Answer both questions. If the unit may be covered, we will direct you to the manufacturer first. Your answers stay in this page unless you submit a repair request.
Choose both answers to see the recommended route.
Start with the manufacturer
The unit is under warranty or its coverage is uncertain, so no local repair lead form is shown. Ask the manufacturer about warranty support and keep proof of purchase.
Manufacturer route
Official support
Active support recorded
This brand is recorded as active in the Australian market.
Quantum Energy’s current Australian after-sales page publishes technical-support, service-request and warranty-request routes.
Status checked · Research source
Official support phone: 1800 644 705
Request local repair or replacement help
We will send this request to the site founder, who may share it with a suitable local provider only after you consent below. Submission does not guarantee provider availability.
Official source
Where this result comes from
Quantum Energy Technologies. Quantum Domestic Heat Pump Owner Manual QDC0030PD-11, PDF page 26. Retrieved .