V2 external controller and heat pump PCB error-code display

16 documented fault codes, shared only by the compatible models listed here.

In the display order below, the held evidence set runs from Reclaim Energy REHP-CO2-160GL-V2 to Reclaim Energy REHP-CO2-400SST-V2; its published labels start with E1 and end with U2. The source and each model-mapping record remain visible on this page.

Compatible models

This result is published only for the models explicitly covered by the source evidence.

  • Reclaim EnergyREHP-CO2-160GL-V2
  • Reclaim EnergyREHP-CO2-160SST-V2
  • Reclaim EnergyREHP-CO2-250GL-V2
  • Reclaim EnergyREHP-CO2-250SSEW-V2
  • Reclaim EnergyREHP-CO2-250SST-V2
  • Reclaim EnergyREHP-CO2-315DX-V2
  • Reclaim EnergyREHP-CO2-315GL-V2
  • Reclaim EnergyREHP-CO2-315SSEW-V2
  • Reclaim EnergyREHP-CO2-315SSQ-V2
  • Reclaim EnergyREHP-CO2-315SST-V2
  • Reclaim EnergyREHP-CO2-400DX-V2
  • Reclaim EnergyREHP-CO2-400GL-V2
  • Reclaim EnergyREHP-CO2-400SST-V2

Published codes

Fault code

E1

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as a main printed circuit board failure.

A licensed technician confirms the actual cause.

The manufacturer's documentation indicates this fault may clear after power is switched off at the isolator for a few minutes. Only do this if the isolator is accessible without opening anything, and never repeatedly.

View the canonical E1 result

Fault code

E6

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as a compressor start-up failure.

A licensed technician confirms the actual cause.

View the canonical E6 result

Fault code

E8

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as a stop triggered by detected input overcurrent.

A licensed technician confirms the actual cause.

View the canonical E8 result

Fault code

H6

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as abnormal compressor revolution.

A licensed technician confirms the actual cause.

View the canonical H6 result

Fault code

H8

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as a current detection error.

A licensed technician confirms the actual cause.

The manufacturer's documentation indicates this fault may clear after power is switched off at the isolator for a few minutes. Only do this if the isolator is accessible without opening anything, and never repeatedly.

View the canonical H8 result

Fault code

H9

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as an outdoor temperature sensor error.

A licensed technician confirms the actual cause.

View the canonical H9 result

Fault code

HC

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as an outgoing water temperature sensor error.

A licensed technician confirms the actual cause.

View the canonical HC result

Fault code

J3

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as a discharge temperature sensor error.

A licensed technician confirms the actual cause.

View the canonical J3 result

Fault code

J5

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as a suction temperature sensor error.

A licensed technician confirms the actual cause.

View the canonical J5 result

Fault code

J6

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as a defrost temperature sensor error.

A licensed technician confirms the actual cause.

View the canonical J6 result

Fault code

J8

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as a return water temperature sensor error.

A licensed technician confirms the actual cause.

View the canonical J8 result

Fault code

L4

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as a module temperature error at 90°C or higher.

A licensed technician confirms the actual cause.

View the canonical L4 result

Fault code

L5

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as detected output overcurrent.

A licensed technician confirms the actual cause.

View the canonical L5 result

Fault code

P4

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as a module sensor error.

A licensed technician confirms the actual cause.

The manufacturer's documentation indicates this fault may clear after power is switched off at the isolator for a few minutes. Only do this if the isolator is accessible without opening anything, and never repeatedly.

View the canonical P4 result

Fault code

U0

Red — urgent safety concern

Red means the documented fault involves safety-critical, leak, electrical, refrigerant, lockout or overheat language.

Documented as a stop triggered by detection of gas leakage.

A licensed technician confirms the actual cause.

View the canonical U0 result

Fault code

U2

Amber — service attention

Amber means the fault needs attention; contact the manufacturer or a licensed technician if it persists.

Documented as a power voltage error.

A licensed technician confirms the actual cause.

The manufacturer's documentation indicates this fault may clear after power is switched off at the isolator for a few minutes. Only do this if the isolator is accessible without opening anything, and never repeatedly.

View the canonical U2 result

Official source

Where this result comes from

Reclaim Energy. Reclaim Energy V2 Installation Manual, Issue 15 (June 2026). Retrieved .

Report a problem with this page